UPS on Rent in Haryana
Reliable Power, Uninterrupted Performance!
Powergen Online UPS is generator compatible, Power Factor Corrected UPS with regenerative load bank.
The UPS is utility friendly and generator compatible and prevents the overrating of electrical wires, reduce reflected harmonies back to the source.
Designed for harsh electrical and environmental conditions this model is a long life design;. offers superior levels of protection against all the input power-related problems and provides regenerated, clean, network grade, high quality power to the connected loads.
Industrial design – Designed to handle high inrush current and the transformer is designed to handle the load harmonic current which heats up the inverter transformer.
Technical Specification
| RATED POWER (KVA) | 1KVA TO 15KVA | 5KVA To 40KVA | 5KVA TO 15KVA | 6KVA TO 300KVA |
| PHASE | 1 PHASE - 1 PHASE | 3 PHASE - 1 PHASE | 1 PHASE - 3 PHASE | 3 PHASE - 3 PHASE |
| INPUT | ||||
| INPUT VOLATGE | 170-270 VAC (3 WIRES) | 310-470 VAC 3 PHASE (4/5 WIRES) | 170 -270 VAC (3 WIRES) | 310-470 VAC (4/5 WIRES) |
| INPUT FREQUENCY | 50Hz | + 10% | ||
| OUTPUT | ||||
| POWER FACTOR | 0.8 (Standard), | 0.9 or 1 (Optional) | ||
| OUTPUT VOLTAGE | 220V/230V/240V AC +1%Fixed as per Requirement | 220V/230V/240V AC +1%Fixed as per Requirement | 380V/400V/415V AC + 1% Fixed as per Requirement | 380V / 400V 415V AC + 1%Fixed as per Requirement |
| FREQUENCY | 50Hz + 0.1% or | 60Hz as required | ||
| WAVEFORM | Pure | Sine wave | ||
| THDv | <3% on | Linear Load | ||
| EFFICIENCY | Up to | 93.7% | ||
| OVERLOAD CAPACITY | 125% for 10 Minutes, | 150% for 60 Seconds | ||
| ISOLATION TRANSFORMER | Galvanised Isolation | Transformer | ||
| TRANSIENT RECOVERY | Within | 3 cycles | ||
| BATTERY | ||||
| DC VOLATGE | 48V-192V | 192V/240V/360V DO | 180V-192 VDC | 360V-480VDC |
| CHARGING TIME | <10 Hrs. | to 98% | ||
| CHARGING CURRENT | 8-10% of rated | Battery AH | ||
| CHARGER | Trickle, | Float & Boost | ||
| SYSTEM FEATURES | ||||
| LCD DISPLAY | Input Output | Voltage, Input output Frequency, | Load, Battery Percentage | (or as required) |
| LED Indication | Mains, | AC Mode, DC Mode, | Charging, Low Battery and Over | Load |
| ALARM | Battery Low, Abnormal Power | Supply, UPS failure, | Overload | |
| PROTECTION | Reverse polarity of | battery, Battery Low & Over | Voltage, Overload, short off, | circuit, Input-Output Cut- |
| TRANSFER TIME | 0 | Milliseconds | ||
| ENVIRONMENT | ||||
| TEMPRATURE | Operating 0°-45°C, | Storage : -10°C-55°C | ||
| HUMIDITY | 0-95%RH | Non-Condensing/<1500M | ||
| NOISE | Low Audible | Noise Level | ||
| COOLING | Forced Air | Cooling by Fans | ||
| STANDARDS | ||||
| QUALITY | ISO 9000, | ISO 14000 | ||
| ENCLOSURE | IP-21 | OR IP-31 | ||
| COMPONENT | High Quality & | Reputed Make Alcon, Rescon, | Mitsubishi, Semicron, | Philips, CDIL, Keltrons |
| COMMUNICATION INTERFACE | ||||
| OPTIONAL | Ethernet/SNMP/Modbus/RS-485 |