Online UPS for Laser in Noida

Reliable Power, Uninterrupted Performance!

Powergen Online UPS for Laser is generator compatible, Power Factor Corrected UPS with regenerative load bank.

The Online UPS for Laser is utility friendly and generator compatible and prevents the overrating of electrical wires, reduce reflected harmonies back to the source.

Designed for harsh electrical and environmental conditions this model is a long life design;. offers superior levels of protection against all the input power-related problems and provides regenerated, clean, network grade, high quality power to the connected loads.

Industrial design – Designed to handle high inrush current and the transformer is designed to handle the load harmonic current which heats up the inverter transformer.

Technical Specification

RATED POWER (KVA)1KVA TO 15KVA5KVA To 40KVA5KVA TO 15KVA6KVA TO 300KVA
PHASE1 PHASE - 1 PHASE3 PHASE - 1 PHASE1 PHASE - 3 PHASE3 PHASE - 3 PHASE
INPUT
INPUT VOLATGE170-270 VAC (3 WIRES)310-470 VAC 3 PHASE (4/5 WIRES)170 -270 VAC (3 WIRES)310-470 VAC (4/5 WIRES)
INPUT FREQUENCY50Hz+ 10%
OUTPUT
POWER FACTOR0.8 (Standard),0.9 or 1 (Optional)
OUTPUT VOLTAGE220V/230V/240V AC +1%Fixed as per Requirement220V/230V/240V AC +1%Fixed as per Requirement380V/400V/415V AC + 1% Fixed as per Requirement380V / 400V 415V AC + 1%Fixed as per Requirement
FREQUENCY50Hz + 0.1% or60Hz as required
WAVEFORMPureSine wave
THDv<3% onLinear Load
EFFICIENCYUp to93.7%
OVERLOAD CAPACITY125% for 10 Minutes,150% for 60 Seconds
ISOLATION TRANSFORMERGalvanised IsolationTransformer
TRANSIENT RECOVERYWithin3 cycles
BATTERY
DC VOLATGE48V-192V192V/240V/360V DO180V-192 VDC360V-480VDC
CHARGING TIME<10 Hrs.to 98%
CHARGING CURRENT8-10% of ratedBattery AH
CHARGERTrickle,Float & Boost
SYSTEM FEATURES
LCD DISPLAYInput OutputVoltage, Input output Frequency,Load, Battery Percentage(or as required)
LED IndicationMains,AC Mode, DC Mode,Charging, Low Battery and OverLoad
ALARMBattery Low, Abnormal PowerSupply, UPS failure,Overload
PROTECTIONReverse polarity ofbattery, Battery Low & OverVoltage, Overload, short off,circuit, Input-Output Cut-
TRANSFER TIME0Milliseconds
ENVIRONMENT
TEMPRATUREOperating 0°-45°C,Storage : -10°C-55°C
HUMIDITY0-95%RHNon-Condensing/<1500M
NOISELow AudibleNoise Level
COOLINGForced AirCooling by Fans
STANDARDS
QUALITYISO 9000,ISO 14000
ENCLOSUREIP-21OR IP-31
COMPONENTHigh Quality &Reputed Make Alcon, Rescon,Mitsubishi, Semicron,Philips, CDIL, Keltrons
COMMUNICATION INTERFACE
OPTIONALEthernet/SNMP/Modbus/RS-485

Applications

CNC
Machine

CT & MRI
scanners

Offset & digital
printers

Process
automation

Vertical milling
machines

Multiplex and
cinema halls

Pharma
Processing

Research
Labs

Laser Cutting
Machines

Automated
Manufacturing